During operation, several common faults may occur. Key issues and solutions are summarized below:

I. Failure to briquetting
Discussed in detail in the earlier article 《Reasons why the briquetting machine fails to briquetting》. Refer to this article via the "Relevant Articles" link below it.
II. Insufficient briquetting ball Strength
Main causes:
1:Incorrect binder ratio → Re-optimize formula
2:Inadequatebriquetting pressure → Adjust pressure parameters
3:Abnormal material moisture → Strictly control moisture within process range
III. Hydraulic System Failure
With advancing hydraulic technology, common failures have shifted from oil issues to relief valve faults. For mature equipment, ~80% hydraulic failures can be resolved by replacing relief valves.
IV. Motor Overheating
Causes & solutions:
1:Sudden feed changes/material property variations → Adjust feed rate to rated capacity
2:High ambient temperature → Install industrial cooling fans to enhance forced convection
V. Excessive Vibration
Causes & solutions:
●Bearing issues:
○Damage → Replace bearings
○Insufficient lubrication → Replenish grease promptly
●Mechanical looseness → Regularly inspect and tighten all bolts
Note: This covers only typical faults. For specific on-site solutions, contact our technical team for detailed support.